SPring-8, the large synchrotron radiation facility

Skip to content
» JAPANESE
Personal tools
 

Diffraction enhanced imaging

  • Only SPring-8
  • For beginners

Inquiry number

SOL-0000001152

Beamline

BL20B2 (Medical and Imaging I)

Scientific keywords

A. Sample category biology, medicine, research on method, instrumentation
B. Sample category (detail) organic material, macromolecule, biology (in vivo), biology (in vitro), organism, cell, biological material, biomolecule, crystal, biomolecule, noncrystal
C. Technique X-ray diffraction, absorption and its secondary process
D. Technique (detail) reflection, refraction
E. Particular condition 2D imaging, interface, room temperature
F. Photon energy X-ray (4-40 keV), X-ray (> 40 keV)
G. Target information morphology

Industrial keywords

level 1---Application area Pharmaceuticals
level 2---Target process analytical technology (PAT)
level 3---Target (detail) drug
level 4---Obtainable information density, crack, crevice, molphology
level 5---Technique imaging

Classification

A80.50 Pharmaceuticals

Body text

DEI (Diffraction Enhanced Imaging) is a unique technique to obtain an x-ray image of an object based on the difference in the refractive indices. The technique is applicable to any objects that require observation at a spatial resolution of 0.02 - 0.2 mm and gives an image with a unique contrast which provides information on the fine structure of the object. The figure shows images of two Perspex cylinders which show very unique contrast.

 

[ K. M. Pavlov, T. E. Gureyev, D. Paganin, Y. I. Nesterets, M. J. kitchen, K. K. W. Siu, J. E. Gillam, K. Uesugi, N. Yagi, M. J. Morgan and R. A. Lewis, Nuclear Instruments and Methods in Physics Research A 548, 163-168 (2005), Fig. 2,
©2005 Elsevier Science Publisher ]

Source of the figure

Original paper/Journal article

Journal title

Nuclear Instruments and Methods in Physics Research A 548 (2005) 163–168

Figure No.

2

Technique

Source of the figure

No figure

Required time for experimental setup

1 shift(s)

Instruments

References

Document name
Nuclear Instruments and Methods in Physics Research A 548 (2005) 163–168

Related experimental techniques

Questionnaire

The measurement was possible only in SPring-8. Impossible or very difficult in other facilities.
This solution is an application of a main instrument of the beamline.

Ease of measurement

Easy

Ease of analysis

Easy

How many shifts were needed for taking whole data in the figure?

Less than one shift

Last modified 2006-03-31 16:31