Liquid Hg
問い合わせ番号
SOL-0000001153
ビームライン
BL04B2(高エネルギーX線回折)
学術利用キーワード
A. 試料 | 無機材料 |
---|---|
B. 試料詳細 | 液体・融体 |
C. 手法 | X線回折 |
D. 手法の詳細 | 小角散乱 |
E. 付加的測定条件 | 高温(>>500度) |
F. エネルギー領域 | X線(4~40 keV) |
G. 目的・欲しい情報 | 構造変化 |
産業利用キーワード
階層1 | 工業材料, その他 |
---|---|
階層2 | |
階層3 | |
階層4 | 液体・非晶質構造 |
階層5 | 小角散乱 |
分類
M20.10 小角散乱
利用事例本文
The use of 38 keV x-rays allows us to measure small-angle x-ray scattering data of liquid heavy metal (e.g. Hg) under high temperature and high pressure with a transmission geometry. The small angle scattering experiment using 38 keV x-rays reveals the metal - nonmetal transition in liquid Hg. Figure shows small-angle scattering spectra of liquid Hg. As can be seen from this figure, distinct small-angle scattering can observed under metal - nonmetal transition, which suggests that density fluctuation is a trigger of metal - nonmetail transition.
Fig. X-ray small-angle scattering spectra for liquid Hg.
[ K. Tamura, M. Inui, K. Matsuda and D, Ishikawa, Rigaku Journal 35, 28-36 (2004), Fig. 9,
©2004 Rigaku ]
画像ファイルの出典
原著論文/解説記事
誌名
リガクジャーナル35(2)2004,28-36
図番号
9
測定手法
X-ray small-angle scattering technique is a powerful tool to get the structural information, e.g. density fluctuation of liquid metal. In order to get high-quality data of liquid heavy metal, it is essential to use high-energy x-rays, which have sufficient penetration ability. The high-flux and high-energy x-rays from SPring-8 make it possible to get small-angle scattering data of small volume liquid under high-pressure and high-temperature.
画像ファイルの出典
図なし
測定準備に必要なおおよその時間
8 時間
測定装置
装置名 | 目的 | 性能 |
---|---|---|
Small angle X-ray scattering diffractometer | to get small-angle scattering data | 38 keV |
参考文献
関連する手法
アンケート
SPring-8だからできた測定。他の施設では不可能もしくは難しい
本ビームラインの主力装置を使っている
ユーザー持ち込み装置を使った
測定の難易度
熟練が必要
データ解析の難易度
熟練が必要
図に示した全てのデータを取るのにかかったシフト数
10シフト以上