SPring-8, the large synchrotron radiation facility

Skip to content
» JAPANESE
Personal tools
 

BL20B2 OUTLINE

Inquiry number

INS-0000000314

ABSTRACT

  The bending-magnet beamline is allocated to medical applications and various imaging techniques in the energy range of 5-113 keV. The main optics is a fixed-exit double crystal monochromator. The X-ray beam produced by the bending magnet passes out of the experimental hall surrounding the storage ring and enters the biomedical imaging center. The experiments are performed in the experimental hall and the biomedical imaging center for alternative operations.

AREA OF RESEARCH

  • The medical research mainly involves micro-radiography, micro-tomography and refraction-contrast imaging on biological specimens and small animals.
  • Imaging techniques involve the evaluation and development of various kinds of optical elements for novel imaging techniques.

KEYWORDS

  • Scientific field
    Preclinical radiographic imaging, preserved tissue specimen imaging, materials science, Earth science, X-ray optics, ultra-small-angle scattering, X-ray fluorescence analysis of large materials
  • Equipment
    High resolution X-ray detector, high precision diffractometer, micro-angiography, micro-tomography, topography, small-field micro-radiography, large-field scanned projection radiography, plain-wave wide-beam radiography, multi-crystal diffraction topography

SOURCE AND OPTICS

Schematic View of Beamline

  • X-rays at Sample

    Critical energy 28.9 keV
    Beam divergence 1.5 mrad (Horizontal)
    0.06 mrad (Vertical)
    Energy range Si 311 : 8.4 ∼ 72.5 keV
    Si 111 : 5.0 ∼ 37.5 keV
    Si 511 : 13.5 ∼ 113.3 keV
    Beam size 1 about 75 mm (H) × 5 mm (V) in the experimental hutch 1 located in the experimental hall (Si 311)
    Beam size 2 about 300 mm (H) × 20 mm (V) in the hutches located in the biomedical imaging center (Si 311)

    Fig.2. Overview of beamline

    Fig.3. Beamline in the experimental hall

EXPERIMENTAL STATIONS

PUBLICATION SEARCH

* Sorry, Some parts of results are displayed using Japanese characters.

 

CONTACT INFORMATION

Please note that each e-mail address is followed by "@spring8.or.jp."

Kentaro UESUGI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : ueken

Keiji UMETANI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : umetani

Last modified 2010-04-08 13:33