BL28B2 Optics hutch 2
Inquiry number
INS-0000000371
Optics hutch 2
The equipment in OH 2 is energy-dispersive XAFS system, experimental system for biomedical application experiments, diffractometer and X-ray tomographic stage for long objects.
Samples can be cooled down to 3.8 K by He cryostat and also heated up to 1770 K by infrared heater.
- Energy-dispersive XAFS system
- The main equipment of the DXAFS system consists of a polychromator with a bent silicon crystal, a higher-harmonic-rejecting mirror, and a CCD coupled with a scintillating screen and a lens system.
DXAFS
- The main equipment of the DXAFS system consists of a polychromator with a bent silicon crystal, a higher-harmonic-rejecting mirror, and a CCD coupled with a scintillating screen and a lens system.
- Experimental system for biomedical application
- Micro-angiography for small animals
- Large field of view, High-resolution X-ray microtomography
- Radiation therapy using X-ray microbeam
- diffractometer
- Energy-dispersive X-ray diffraction and white X-ray topography
- Components are shown in Table.
- Various detectors can be set on detector arm.
- Equipments for sample environment can be set on Ry swivel stage.
- X-ray tomographic stage for long objects
- System is composed of high precision rotational stage, swivel stages, horizontal and vertical translation stages.
- Long stroke in vertical direction (±300mm)
- Movable system with castor wheel
- Intensity measuring devices
- Ionization chamber for I0 monitoring
- NaI scintillation detectors
- Ge solid state detector (SSD)
- Multi-channel Analyzer with ADC&HV module for SSD
- NIM-based bins, HV's, amplifiers, single-channel analyzers, voltage-to-frequency converters (VFC) for ionization chambers.
- Current amplifiers and pico-ammeters
- Digital multi-meter
- Image recording devices
- Beam monitor with CCD
- Flat panel sensor (C7942CA-02, Hamamatsu Photonics K.K.)
- Sample environment
- Infrared heater (up to 1770 K)
- Cryostat (3.8 K)
- Accessories
- Optical microscope with CCD camera connected to a PC based data analysis system
- Simple darkroom for photographic processing
- Constant low temperature (5°C) cabinet for keeping films, plates and photo-chemicals
name resolution Range ω1 1/1000 deg. 360 deg. 2θ 1/1000 deg. 360 deg. X 2/1000 mm ± 20 mm Y 2/1000 mm ± 20 mm Rx swivel 1/1000 deg. ± 7.5 deg. Ry swivel 1/1000 deg. ± 7.5 deg. Z 2/1000 mm ± 50 mm χ 1/1000 deg. 360 deg. detector arm 2/1000 mm ± 200 mm ω2 1/1000 deg. 360 deg.