大型放射光施設 SPring-8

コンテンツへジャンプする
» ENGLISH
パーソナルツール
 

BL09XU OUTLINE

問い合わせ番号

INS-0000000302

ABSTRACT

 BL09XU is dedicated to hard X-ray photoelectron spectroscopy (HAXPES). This beamline is a standard hard X-ray beamline with a 32 mm-period linear undulator and a liquid-nitrogen cooled monochromator. Different types of HAXPES instruments are installed in tandem in experimental hutch 1 and 2, allowing the use of each instrument depending on the purpose of measurement. In BL09XU, the advanced HAXPES measurement using the high-performance optical system is available, including double channel-cut monochromators, double x-ray phase retarders, long-length focusing mirrors, and so on. An example of measurement using these advanced optics is a resonant HAXPES measurement. By obtaining HAXPES spectra with sweeping the incident x-ray energy across an absorption edge, we can perform elemental and orbital selective electronic structure analysis.

AREA OF RESEARCH

  • Electronic properties at the buried interface with high energy resolution
  • Element and orbital specific electronic state using the tunable photon energy
  • Three-dimensional spatial resolved analysis of the chemical states using the combination micro focusing beam and angle-resolved measurement
  • X-ray polarization tunability with phase retarder and analysis for observing magnetic effects
  • Various applications both in basic and applied research fields under low temperatures

KEYWORDS

  • Technique
    HAXPES, Combined measurement with X-ray absorption spectroscopy (XAS)
  • Equipment
    HAXPES analyzer, Long-length focusing mirror, Channel-cut monochromator, X-ray phase plate, Wide-acceptance-angle electrostatic lens (WAAELs), Silicon drift detector (SDD) for XAS measurement

SOURCE AND OPTICS

  • Beamline layout
  • X-rays at Sample
    Energy range 4.9-12 keV (Si 220 DCCM, Si 311 DCCM) / 6,8,10 keV (Si 333/444/555 CCM)
    Resolution of X-ray <300 meV @ 4.9-12 keV (Si 220/311 DCCM), 36 meV @ 7.94 keV (Si 444 CCM)
    Flux 6.0 × 1012 phs/s (E=7.94 keV @ 100 mA, Si 311 DCCM)
    Beam size(FWHM) 1 (V) × 20 (H) µm2 (EH1), 1 (V) × 11 (H) / 1 (V) × 1 (H) µm2 (EH2)
    Linear/Circular polarization rate(X-ray phase plate) >90% @ E=5.95-9.5 keV

EXPERIMENTAL STATIONS

  • High-energy-resolution HAXPES
  • Three-dimensional special resolved HAXPES

PUBLICATION SEARCH

* Sorry, Some parts of results are displayed using Japanese characters.

BL09XU PUBLICATION SEARCH / BL47XU PUBLICATION SEARCH

CONTACT INFORMATION

Please note that each e-mail address is followed by "@spring8.or.jp."

Akira YASUI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : a-yasui

Yasumasa TAKAGI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : ytakagi

Jiayi Tang
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : jiayi.tang

最終変更日