BL10XU (High Pressure Research)

Scientific keywords

A. Sample category research on method, instrumentation
B. Sample category (detail) insulator, ceramics, solid-state crystal
C. Technique X-ray diffraction
D. Technique (detail) powder diffraction
E. Particular condition microbeam (> 10 µm), high pressure (DAC)
F. Photon energy X-ray (> 40 keV)
G. Target information crystal structure

Industrial keywords

level 1---Application area others
level 2---Target
level 3---Target (detail)
level 4---Obtainable information density, elastic modulus
level 5---Technique diffraction

Classification

M10.20 powder diffraction

Body text

This application is expected as a new pressure determination up to multi-megabars pressure region. The first-order Raman spectra of diamond anvils of DAC have been measured at the pressure up to 300GPa. In order to determine the volume of the pressure standard, powder x-ray diffraction experiments were carried out at 300K on BL10XU (Y. Akahama et al., Journal of Applied Physics, 96-7(2004)3748).

Figure. The pressure dependence of the Raman shift of diamond.

[ Y. Akahama and H. Kawamura, Journal of Applied Physics 96, 3748-3751 (2004), Fig. 2,
©2004 American Institute of Physics ]

 

Source of the figure

Private communication/others

Description

兵庫県立大 赤浜裕一氏提供

Technique

The high pressure research beamline BL10XU is designed to perform the X-ray diffraction structure analysis under high-pressure and low/high temperature, using the high brilliance X-rays from the in-vacuum type undulator.  The monochromatic and focused X-rays irradiate the sample enclosed in a DAC system, which can generate the pressure up to 300 GPa. The most of the conventional limitations (extremely small size sample area (<100mm), limited diffraction windows, x-ray absorption by diamond and so on) for the DAC high pressure diffraction experiment was extended and upgraded to the high resolution, high angular resolution and high counting statistics diffraction experiment as well as rapid data measurement.

Source of the figure

Presentation material for Beamline Report

Required time for experimental setup

4 hour(s)

Instruments

Instrument Purpose Performance
DAC diffractometer high pressure x-ray diffraction X-ray diffraction at the pressure up to 300GPa

References

Related experimental techniques

powder x-ray diffraction, single crystal x-ray diffraction, Raman spectroscopy

Questionnaire

The measurement was possible only in SPring-8. Impossible or very difficult in other facilities.
This solution is an application of a main instrument of the beamline.

Ease of measurement

With a great skill

Ease of analysis

Easy

How many shifts were needed for taking whole data in the figure?

Four-nine shifts