交換結合Co/Cu多層膜のCu層に誘起された磁気分極の観測

  • Only SPring-8

Inquiry number

SOL-0000001611

Beamline

BL39XU (X-ray Absorption and Emission Spectroscopy)

Scientific keywords

A. Sample category inorganic material
B. Sample category (detail) magnetic material, synthetic multilayer
C. Technique X-ray diffraction
D. Technique (detail) magnetic scattering
E. Particular condition polarization (circular), room temperature, magnetic field (< 2 T)
F. Photon energy X-ray (4-40 keV)
G. Target information spin/magnetism

Industrial keywords

level 1---Application area storage device
level 2---Target HD,MO
level 3---Target (detail) magnetic layer, magnetic head, spin valve
level 4---Obtainable information magnetic moment, interface magnetic structure
level 5---Technique magnetic scattering, magnetic Compton scattering, PEEM

Classification

A80.14 magnetic materials, M25.10 magnetic scattering

Body text

円偏光放射光X線を用いた共鳴磁気散乱は、磁性膜内部の磁化分布を調べることのできるユニークな手法です。この手法を用いることで、3d 遷移金属元素や希土類元素からなる磁性多層膜の各層での深さ方向の磁化分布を測定することができます。この方法は非常に高感度なので、Cuなどの非磁性層に誘起された微小な磁化の分布も決定することができます。図に示すのは、交換結合多層膜 [Co(1.25 nm)/Cu(3.88 nm)]50 について測定した(a) Cu層および(b) Co層からの磁気散乱ピークです。この結果から、Co層内の磁化は一様に分布しているのに対して、Cu層内の磁化は界面から層の内部向かって減衰しながら正負に振動する複雑な分布をしていることがわかりました。

図. 交換結合Co/Cu多層膜のX線共鳴磁気散乱ピーク

[ Y. Hayasaki, K. Ishiji, H. Hashizume, N. Hosoito, K. Omote, M. Kuribayashi, G. Srajer, J. C. Lang and D. Haskel, Journal of Physics :Condensed Matter 16, 1915-1925 (2004), Fig. 10,
©2004 Institute of Physics and IOP Publishing, Ltd. ]

 

Source of the figure

Original paper/Journal article

Journal title

Y. Hayasaki et al., J. Phys.: Condens. Matter 16, 1915 (2004).

Figure No.

Fig. 10

Technique

X線共鳴磁気散乱データは、右回りと左回りの円偏光X線に対する回折強度のわずかな差を測定することによって得られます。この例では、X線のエネルギーをCo (7723 eV) およびCuの共鳴吸収端 (8992 eV) に合わせることにより、それぞれの元素を含む層からの磁気散乱ピークが得られます。

Source of the figure

No figure

Required time for experimental setup

2 shift(s)

Instruments

Instrument Purpose Performance
磁気散乱用2軸回折計 共鳴X線磁気散乱測定 角度分解能 0.36秒/ステップ。4軸回折計付き

References

Document name
Y. Hayasaki, K. Ishiji, H. Hashizume, N. Hosoito, K. Omote, M. Kuribayashi, G. Srajer, J. C. Lang, and D. Haskel, J. Phys.: Condens. Matter 16, 1915 (2004).

Related experimental techniques

XMCD, X線磁気円二色性, 元素選択磁化測定, 磁気抵抗測定, SQUID磁化測定, VSM磁化測定

Questionnaire

The measurement was possible only in SPring-8. Impossible or very difficult in other facilities.
With user's own instruments.