SPring-8, the large synchrotron radiation facility

Skip to content
» JAPANESE
Personal tools
 

BL02B1 OUTLINE

Inquiry number

INS-0000001275

ABSTRACT

BL02B1 is a station to carry out high-energy X-ray diffraction experiments on single crystals and is equipped with a semiconductor detector and a 4-axis (ψ, υ, φ, 2θ) diffractometer. The beamline uses X-rays from the bending magnet source incident onto a double-crystal monochromator, which by design enables achieving high throughput and monochromatic X-rays in the range of 8-115 keV. X-rays with energy in the range of 20-60 keV are being used for single crystal structure analysis while a standard energy of 30 keV is used in most experiments. Recently, the beamline has been upgraded with an emphasis on precise structural analysis of functional materials.

FIELDS OF RESEARCH

The beamline is focused on crystal structure determination of both organic and inorganic functional materials. A two-dimensional semiconductor detector is used for rapid data collection with high statistical accuracy so that precise crystal structure analysis can be performed at the electron density level. The use of high-energy X-rays makes it possible to determine the structure of inorganic materials, even those containing heavy atoms, with almost negligible absorption effects.

KEYWORDS

  • Scientific field
    Crystal structure analysis, High-energy X-ray diffraction, Charge density level analysis
  • Equipment
    4-axis diffractometer, Low-temperature N2 and He gas flow equipment (20-400 K), High-temperature N2 gas flow equipment (300-800 K)
  • Various attachments
    Gas adsorption equipment for in-situ observation, UV irradiation equipment

SOURCE AND OPTICS

A double-crystal monochromator and a platinum-coated total reflection mirror are installed downstream of the monochromator in the optics hutch of BL02B1. Monochromatic synchrotron X-rays are obtained using a double-crystal monochromator (energy resolution: ΔE/E=10-4). The second crystal of the double-crystal monochromator can be sagittally bent for horizontal focusing. The downstream mirror can focus X-rays vertically by adjusting the amount of bend. This total reflection mirror is used not only for collimation and vertical focusing of X-rays but also for removal of higher-order harmonics (used at energies lower than 30 keV). The minimum beam size at the sample position is about 0.2 mm (FWHM) vertical height and 0.2 mm (FWHM) horizontal width. Currently, the maximum photon flux is about 1010 photons/sec at the sample position.


  • X-rays at Sample

      Energy range 8 - 115 keV
      Energy resolution ΔE/E = 10-4
      Photon flux <1010 photons/s
      Minimum beam size 0.2(H) × 0.2(V) mm2(FWHM)

EXPERIMENTAL STATIONS

A two-dimensional (2D) semiconductor detector and a 4-axis diffractometer are installed in the experimental hutch.

PUBLICATION SEARCH

* Sorry, Some parts of results are displayed using Japanese characters.

BL02B1 PUBLICATION SEARCH

CONTACT INFORMATION

Please note that each e-mail address is followed by "@spring8.or.jp."

Yasuhiko IMAI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-2750
Fax : +81-(0)791-58-0830
e-mail : imai

Kouhei ICHIYANAGI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : kichiyanagi

Yuiga NAKAMURA
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : ynakamura

Sumit Maity
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : sumit050491

Toshiyuki SASAKI
SPring-8 / JASRI
1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198
Phone : +81-(0)791-58-0833
Fax : +81-(0)791-58-0830
e-mail : toshiyuki.sasaki

Last modified 2023-12-05 09:37